Home > Pruebas de
Corrosión
> Sistema Chlorimeter >


Chloride Field Test System™
Determines Chloride Concentrations of Samples in the Field

Chloride Field Test System<br>Field Test System to Determine the Chloride Ion Concentration in Wet Or Dry Concrete.
Chloride Field Test System


 
Questions?
Call us for more information!
Price $3,100.00



Product Code: C-CL-2000


Add Extended Warranty:
CHLORIDE Field TEST SYSTEM Extended Warranty [Add $400.00]

Qty:  
Especificaciones
 

If you are not sure on what item to buy, please see our Purchasing Notes below or contact us and we'll be glad to assist you on your order.

We also offer an "Add extended warranty" option to your purchased instrument! Just add it to your cart.



Chloride Test System

A chloride laboratory in a briefcase for wet or dry concrete.


Purchasing Notes

Consumables:


Applications

  • Service life prediction

  • Corrosion analysis


Features & Benefits

  • Fast - Results within minutes at the site.

  • Economical - Low cost per sample compared to laboratory testing.

  • Accurate - Results are comparable to laboratory testing.

  • Covers wide range from 0.002% to 2% chloride by weight.

  • Automatic compensation for changes in ambient temperature.

  • Digital display for direct reading of lbs./cu. yd. and percentage of chloride by weight.

  • Conforms to AASHTO-T- 260.


The Chloride Field Test System measures the amount of chloride present in wet or dry concrete.

The C-CL-2000 produces results on-site, within minutes that are accurate and comparable to expensive laboratory tests. It measures the electrochemical reaction of a weighted sample placed in an extraction liquid. It automatically shows a temperature compensated reading of percent of chlorides on its digital display. A wide range - from 0.002 to 2% chloride by weight - is covered.


Technical

The determination of the chloride ion concentration in concrete is essential in assessing the need for maintenance on, for example, bridge decks and parking structures. The test can also be used to ensure that materials used in new construction are free from potentially harmful chloride ion levels.

With this method, the concentration of acid soluble chlorides is measured. In most cases, this is equivalent to total chloride concentration.

A sample of powder is obtained by drilling and careful quartering. Then an accurately weighed 3 gr. (0.1 oz) sample is dissolved in 20 ml (0.67 fl. oz.) of extraction liquid which consists of a precise, measured concentration of acid. For sampling wet concrete a 3 gr. (0.1 oz.) sample of mortar (i.e. without coarse aggregate) is used.

The chloride ions react with the acid of the extraction liquid in an electrochemical reaction. An electrode, with integral temperature sensor, is inserted into the liquid and the electrochemical reaction measured. A uniquely designed instrument converts the voltage generated by the chloride concentration. The instrument automatically applies the temperature correction and it shows the chloride concentration on a LCD display in either lbs. per cu. yd. or percentage by weight.

Once the sample is obtained, test results can be determined and read in less than five minutes.

To avoid contamination, the electrode should be thoroughly washed with de-ionized water after each test.

Replacement packs, containing twelve bottles of extraction liquid, each for one time use, are available. Five calibration liquids each with known concentrations are supplied with each pack.

These liquids are used to establish the calibration curve, and to check that the system is functioning correctly. Calibration is not required for each use. The calibration liquids are colored to avoid confusion between them and with the extraction liquid.

All equipment necessary to complete the chloride test is supplied in a standard size carrying case.


Components

C-CL 3700
Chloride combination electrode with externally mounted
temperature sensor, cable, and connectors.
C-CL 2020
Battery powered, high impedance, electronic meter, with temperature compensation circuits and microprocessor for direct conversion to percentage of chloride.
C-CL 2012
Replacement pack of 12 jars each with 20 ml (0.67 fl. oz.) of extraction liquid and 5 jars of colored calibration liquid.
C-CL 1030
Bottle of electrode wetting agent.
C-CL 2096
Bulk pack of 100 jars extraction liquid and 20 jars of colored calibration liquid.
C-CL 2050                 
Optional system for compliance with AASHTO-T260.
To meet AASHTO's specification the 3 gm (0.1 oz.) sample is digested in sufficient extraction liquid to bring the volume to 20 ml (0.67 fl. oz).

After 24 hours digestion period this is titrated with 80 ml (2.7 fl. oz.) of solution. The C-CL 2020 electronic meter, in AASHTO mode is then used with chloride electrode to read the concentration of chloride.



Downloadable Document



Comparte tus conocimientos de este producto con otros clientes... Sé el primero en escribir un comentario

Browse for more products in the same category as this item:

Pruebas de
Corrosión
> Sistema Chlorimeter
Pruebas de
Corrosión